<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>nsx-t arşivleri | BURAK AKTAŞ</title>
	<atom:link href="https://www.burakaktas.com/etiket/nsx-t/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.burakaktas.com/etiket/nsx-t/</link>
	<description>Virtualization Technologies Blog</description>
	<lastBuildDate>Wed, 15 Mar 2023 18:26:22 +0000</lastBuildDate>
	<language>tr</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.burakaktas.com/wp-content/uploads/2020/04/cropped-vm_favicon-32x32.png</url>
	<title>nsx-t arşivleri | BURAK AKTAŞ</title>
	<link>https://www.burakaktas.com/etiket/nsx-t/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>vMotioning a VM on NSX-T Data Center segment fails when moving between different segment on a different host</title>
		<link>https://www.burakaktas.com/vmotion-a-vm-on-nsx-t-data-center-segment-fails-when-moving-between-different-segment-on-a-different-host/</link>
		
		<dc:creator><![CDATA[Burak AKTAŞ]]></dc:creator>
		<pubDate>Tue, 14 Mar 2023 10:21:33 +0000</pubDate>
				<category><![CDATA[NSX-T]]></category>
		<category><![CDATA[esxi]]></category>
		<category><![CDATA[nsx-t]]></category>
		<category><![CDATA[vmware]]></category>
		<category><![CDATA[vsphere]]></category>
		<guid isPermaLink="false">https://www.burakaktas.com/?p=3788</guid>

					<description><![CDATA[<p>Merhaba, bugün mesai arkadaşım ile birlikte bir çalışma kapsamında belirli virtual machine&#8217;leri, &#8220;X&#8221; datacenter&#8217;dan, &#8220;Y&#8221; datacenter&#8217;ına vCenter vMotion ile taşıma yaparken karşımıza bir uyarı çıktı. VMware ortamımızın network alt yapısı NSX-T üzerinde koşmakta olup bize &#8220;X&#8221; datacenter&#8217;daki segment&#8217;den &#8220;Y&#8221; datacenter&#8217;daki segment&#8217;e taşıma yapılamayacağının hatasını verdi. Hata üzerindeki KB56991&#8216;i incelediğimizde bize pek yardımcı olmadı. Bizde biraz daha araştırma yapmak zorunda kaldık [&#8230;]</p>
<p>The post <a href="https://www.burakaktas.com/vmotion-a-vm-on-nsx-t-data-center-segment-fails-when-moving-between-different-segment-on-a-different-host/">vMotioning a VM on NSX-T Data Center segment fails when moving between different segment on a different host</a> appeared first on <a href="https://www.burakaktas.com">BURAK AKTAŞ</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-medium-font-size">Merhaba, bugün mesai arkadaşım ile birlikte bir çalışma kapsamında belirli virtual machine&#8217;leri, &#8220;X&#8221; datacenter&#8217;dan, &#8220;Y&#8221; datacenter&#8217;ına <strong>vCenter vMotion</strong> ile taşıma yaparken karşımıza bir uyarı çıktı. VMware ortamımızın network alt yapısı <strong>NSX-T</strong> üzerinde koşmakta olup bize &#8220;X&#8221; datacenter&#8217;daki segment&#8217;den &#8220;Y&#8221; datacenter&#8217;daki segment&#8217;e taşıma yapılamayacağının hatasını verdi.</p>



<figure class="wp-block-image size-large"><a href="https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001.jpg"><img fetchpriority="high" decoding="async" width="1024" height="747" src="https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-1024x747.jpg" alt="" class="wp-image-3790" srcset="https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-1024x747.jpg 1024w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-300x219.jpg 300w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-768x560.jpg 768w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-1536x1121.jpg 1536w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-2048x1495.jpg 2048w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-1000x730.jpg 1000w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-550x400.jpg 550w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-230x168.jpg 230w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-350x255.jpg 350w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_001-480x350.jpg 480w" sizes="(max-width: 1024px) 100vw, 1024px" /></a></figure>



<p class="has-medium-font-size">Hata üzerindeki <a href="https://kb.vmware.com/s/article/56991" target="_blank" rel="noreferrer noopener"><mark style="background-color:rgba(0, 0, 0, 0)" class="has-inline-color has-vivid-cyan-blue-color"><strong>KB56991</strong></mark></a>&#8216;i incelediğimizde bize pek yardımcı olmadı. Bizde biraz daha araştırma yapmak zorunda kaldık ve <a href="https://kb.vmware.com/s/article/85516" target="_blank" rel="noreferrer noopener"><mark style="background-color:rgba(0, 0, 0, 0)" class="has-inline-color has-vivid-cyan-blue-color"><strong>KB85516</strong></mark></a>&#8216;yı bulduk. Bu <strong>KB</strong> bize iki ESXi hostu üzerinde vMotion yapmaya çalıştığımızı ve bu sırada <strong>NSX-T</strong> segmentlerini de değiştirmeye çalıştığımızı anlatıyordu. Fakat bu segment taşımasında mümkün olmayan bir durummuş.</p>



<p class="has-medium-font-size">VM migration sırasında <strong>NSX-T</strong> segment&#8217;i de değiştirmek varsayılan olarak mümkün değilmiş. Bu yüzden bu <strong>vMotion</strong>&#8216;a izin vermek için &#8220;<strong>vCenter Advanced Settings</strong>&#8221; ayarlarından aşağıdaki parametreyi girip &#8220;<strong>TRUE</strong>&#8221; olarak set etmemiz gerekiyormuş.</p>



<p class="has-pale-cyan-blue-background-color has-background has-medium-font-size"><em><strong><mark style="background-color:rgba(0, 0, 0, 0)" class="has-inline-color has-black-color">config.vpxd.network.allowVmotionBetweenLogicalSwitches</mark></strong></em></p>



<p class="has-medium-font-size">Bu nokta da yanılmamak adına, doğruluğu kontrol etmek için VMware&#8217;a case açtık ve onlarda bize bu parametrenin herhangi bir anormal durum yaratmadığını, parametreyi kullanabileceğimizi belirtti.</p>



<figure class="wp-block-image size-large"><a href="https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002.jpg"><img decoding="async" width="1024" height="886" src="https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002-1024x886.jpg" alt="" class="wp-image-3795" srcset="https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002-1024x886.jpg 1024w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002-300x259.jpg 300w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002-768x664.jpg 768w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002-1536x1328.jpg 1536w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002-1000x865.jpg 1000w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002-230x199.jpg 230w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002-350x303.jpg 350w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002-480x415.jpg 480w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_002.jpg 1924w" sizes="(max-width: 1024px) 100vw, 1024px" /></a></figure>



<p class="has-medium-font-size">Burada dikkat edilmesi gereken bir nokta da &#8220;<strong>Advanced Setting</strong>&#8221; üzerinde yapılan işlemler <strong>html5</strong> üzerinden silinememektedir bu yüzden parametreyi dikkatli girmenizi öneririm. Bunu ancak komut satırı üzerinden kaldırabilirsiniz. Bununla ilgili yazıya da aşağıdaki linkden ulaşabilirsiniz.</p>



<p class="has-medium-font-size"><a href="https://www.burakaktas.com/how-to-delete-vcenter-server-advanced-setting/" target="_blank" rel="noreferrer noopener"><strong><mark style="background-color:rgba(0, 0, 0, 0)" class="has-inline-color has-vivid-cyan-blue-color">How to Delete vCenter Server Advanced Setting</mark></strong></a></p>



<p class="has-medium-font-size">Konumuza dönecek olursak parametre&#8217;mizi girdikten sonra yapmamız gereken herhangi bir <strong>reboot</strong> veya <strong>services restart </strong>bulunmamaktadır.</p>



<figure class="wp-block-image size-large"><a href="https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003.jpg"><img decoding="async" width="1024" height="745" src="https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-1024x745.jpg" alt="" class="wp-image-3799" srcset="https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-1024x745.jpg 1024w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-300x218.jpg 300w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-768x559.jpg 768w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-1536x1118.jpg 1536w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-2048x1491.jpg 2048w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-1000x728.jpg 1000w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-550x400.jpg 550w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-230x167.jpg 230w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-350x255.jpg 350w, https://www.burakaktas.com/wp-content/uploads/2023/03/nsx-t_error_003-480x349.jpg 480w" sizes="(max-width: 1024px) 100vw, 1024px" /></a></figure>



<p class="has-medium-font-size">Bir sonraki yazımızda görüşmek üzere. Faydalı olması dileğiyle.</p>
<p><a class="a2a_button_linkedin" href="https://www.addtoany.com/add_to/linkedin?linkurl=https%3A%2F%2Fwww.burakaktas.com%2Fvmotion-a-vm-on-nsx-t-data-center-segment-fails-when-moving-between-different-segment-on-a-different-host%2F&amp;linkname=vMotioning%20a%20VM%20on%20NSX-T%20Data%20Center%20segment%20fails%20when%20moving%20between%20different%20segment%20on%20a%20different%20host" title="LinkedIn" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_facebook" href="https://www.addtoany.com/add_to/facebook?linkurl=https%3A%2F%2Fwww.burakaktas.com%2Fvmotion-a-vm-on-nsx-t-data-center-segment-fails-when-moving-between-different-segment-on-a-different-host%2F&amp;linkname=vMotioning%20a%20VM%20on%20NSX-T%20Data%20Center%20segment%20fails%20when%20moving%20between%20different%20segment%20on%20a%20different%20host" title="Facebook" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_twitter" href="https://www.addtoany.com/add_to/twitter?linkurl=https%3A%2F%2Fwww.burakaktas.com%2Fvmotion-a-vm-on-nsx-t-data-center-segment-fails-when-moving-between-different-segment-on-a-different-host%2F&amp;linkname=vMotioning%20a%20VM%20on%20NSX-T%20Data%20Center%20segment%20fails%20when%20moving%20between%20different%20segment%20on%20a%20different%20host" title="Twitter" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_whatsapp" href="https://www.addtoany.com/add_to/whatsapp?linkurl=https%3A%2F%2Fwww.burakaktas.com%2Fvmotion-a-vm-on-nsx-t-data-center-segment-fails-when-moving-between-different-segment-on-a-different-host%2F&amp;linkname=vMotioning%20a%20VM%20on%20NSX-T%20Data%20Center%20segment%20fails%20when%20moving%20between%20different%20segment%20on%20a%20different%20host" title="WhatsApp" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_email" href="https://www.addtoany.com/add_to/email?linkurl=https%3A%2F%2Fwww.burakaktas.com%2Fvmotion-a-vm-on-nsx-t-data-center-segment-fails-when-moving-between-different-segment-on-a-different-host%2F&amp;linkname=vMotioning%20a%20VM%20on%20NSX-T%20Data%20Center%20segment%20fails%20when%20moving%20between%20different%20segment%20on%20a%20different%20host" title="Email" rel="nofollow noopener" target="_blank"></a></p><p>The post <a href="https://www.burakaktas.com/vmotion-a-vm-on-nsx-t-data-center-segment-fails-when-moving-between-different-segment-on-a-different-host/">vMotioning a VM on NSX-T Data Center segment fails when moving between different segment on a different host</a> appeared first on <a href="https://www.burakaktas.com">BURAK AKTAŞ</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Connection Status for Compute Manager shows as Down in NSX-T Manager</title>
		<link>https://www.burakaktas.com/status-for-compute-manager-shows-as-down-in-nsx-t-manager/</link>
		
		<dc:creator><![CDATA[Burak AKTAŞ]]></dc:creator>
		<pubDate>Sun, 26 Jun 2022 13:59:21 +0000</pubDate>
				<category><![CDATA[NSX-T]]></category>
		<category><![CDATA[esxi]]></category>
		<category><![CDATA[nsx-t]]></category>
		<category><![CDATA[vsphere]]></category>
		<guid isPermaLink="false">https://www.burakaktas.com/?p=3457</guid>

					<description><![CDATA[<p>Merhaba, bu yazımda sizlere NSX-T manager üzerinde connection status down hatasının çözümünü anlatıyor olacağım. NSX-T Manager, System -&#62; Fabric -&#62; Compute Managers&#8217; da Registration Status Registered olarak görünürken, Connection Status Down durumda görünüyor. Down&#8217; ın üzerine gelerek view more details&#8216; ı açtığımızda bize hata hakkında bilgiyi verdiğini görüyoruz. Error kısmı bize kontrol etmemiz gereken şeyleri söylüyor. Bunlardan bir tanesi vCenter [&#8230;]</p>
<p>The post <a href="https://www.burakaktas.com/status-for-compute-manager-shows-as-down-in-nsx-t-manager/">Connection Status for Compute Manager shows as Down in NSX-T Manager</a> appeared first on <a href="https://www.burakaktas.com">BURAK AKTAŞ</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-medium-font-size">Merhaba, bu yazımda sizlere NSX-T manager üzerinde connection status down hatasının çözümünü anlatıyor olacağım.</p>



<figure class="wp-block-image size-large"><a href="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-scaled.jpg"><img loading="lazy" decoding="async" width="1024" height="255" src="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-1024x255.jpg" alt="" class="wp-image-3460" srcset="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-1024x255.jpg 1024w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-300x75.jpg 300w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-768x192.jpg 768w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-1536x383.jpg 1536w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-2048x511.jpg 2048w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-920x229.jpg 920w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-230x57.jpg 230w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-350x87.jpg 350w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_001-480x120.jpg 480w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></a></figure>



<p class="has-medium-font-size"><strong>NSX-T Manager,</strong> System -&gt; Fabric -&gt; Compute Managers&#8217; da <strong>Registration Status</strong> Registered olarak görünürken, <strong>Connection Status</strong> Down durumda görünüyor. Down&#8217; ın üzerine gelerek <strong>view more details</strong>&#8216; ı açtığımızda bize hata hakkında bilgiyi verdiğini görüyoruz.</p>



<figure class="wp-block-image size-full"><a href="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_002-1.jpg"><img loading="lazy" decoding="async" width="1012" height="710" src="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_002-1.jpg" alt="" class="wp-image-3463" srcset="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_002-1.jpg 1012w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_002-1-300x210.jpg 300w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_002-1-768x539.jpg 768w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_002-1-920x645.jpg 920w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_002-1-230x161.jpg 230w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_002-1-350x246.jpg 350w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_002-1-480x337.jpg 480w" sizes="auto, (max-width: 1012px) 100vw, 1012px" /></a></figure>



<p class="has-medium-font-size">Error kısmı bize kontrol etmemiz gereken şeyleri söylüyor. Bunlardan bir tanesi vCenter ile NSX-T manager arasındaki <strong>thumbprint</strong>, diğeri ise yine aynı şekilde vCenter ile NSX-T manager arasındaki <strong>443</strong> ve <strong>80</strong> portlarının erişimi.</p>



<p class="has-medium-font-size">İlk olarak vCenter&#8217; a bağlanıyoruz ve thumbprint&#8217; i aşağıdaki komut ile çekiyoruz. </p>



<p class="has-medium-font-size">Sonrasında NSX-T manager üzerinden eşleşip eşleşmediğini kontrol ediyoruz.</p>



<pre class="wp-block-code has-medium-font-size"><code><strong>openssl x509 -in /etc/vmware-vpx/ssl/rui.crt -fingerprint -sha256 -noout</strong></code></pre>



<figure class="wp-block-image size-large"><a href="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004.jpg"><img loading="lazy" decoding="async" width="1024" height="97" src="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004-1024x97.jpg" alt="" class="wp-image-3464" srcset="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004-1024x97.jpg 1024w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004-300x29.jpg 300w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004-768x73.jpg 768w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004-1536x146.jpg 1536w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004-2048x195.jpg 2048w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004-920x88.jpg 920w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004-230x22.jpg 230w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004-350x33.jpg 350w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_004-480x46.jpg 480w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></a></figure>



<figure class="wp-block-image size-large"><a href="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003.jpg"><img loading="lazy" decoding="async" width="1024" height="793" src="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003-1024x793.jpg" alt="" class="wp-image-3466" srcset="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003-1024x793.jpg 1024w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003-300x232.jpg 300w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003-768x595.jpg 768w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003-1536x1189.jpg 1536w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003-920x712.jpg 920w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003-230x178.jpg 230w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003-350x271.jpg 350w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003-480x372.jpg 480w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_003.jpg 2046w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></a></figure>



<p class="has-medium-font-size">Benim case&#8217; im de vCenter ve NSX-T manager tarafında <strong>thumbprint</strong>&#8216; lerde herhangi bir sorun bulunmuyordu. Bende ikinci hata yolu olan <strong>443</strong> ve <strong>80 </strong>portlarının vCenter ve NSX-T manager arasındaki erişimlerini kontrol ettiğimde<strong> 80</strong> portunun izninin olmadığını gördüm. 80 portuna firewall üzerinden izin verildikten sonra <strong>Connection Status</strong>&#8216; un <strong>UP</strong> olduğunu gördüm.</p>



<figure class="wp-block-image size-large"><a href="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-scaled.jpg"><img loading="lazy" decoding="async" width="1024" height="153" src="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-1024x153.jpg" alt="" class="wp-image-3468" srcset="https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-1024x153.jpg 1024w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-300x45.jpg 300w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-768x115.jpg 768w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-1536x229.jpg 1536w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-2048x306.jpg 2048w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-920x137.jpg 920w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-230x34.jpg 230w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-350x52.jpg 350w, https://www.burakaktas.com/wp-content/uploads/2022/06/nsx-t_005-480x72.jpg 480w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></a></figure>



<p class="has-medium-font-size">Bir sonraki yazımızda görüşmek üzere. Faydalı olması dileğiyle.<a href="https://www.burakaktas.com/#linkedin" target="_blank" rel="noreferrer noopener"></a></p>
<p><a class="a2a_button_linkedin" href="https://www.addtoany.com/add_to/linkedin?linkurl=https%3A%2F%2Fwww.burakaktas.com%2Fstatus-for-compute-manager-shows-as-down-in-nsx-t-manager%2F&amp;linkname=Connection%20Status%20for%20Compute%20Manager%20shows%20as%20Down%20in%20NSX-T%20Manager" title="LinkedIn" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_facebook" href="https://www.addtoany.com/add_to/facebook?linkurl=https%3A%2F%2Fwww.burakaktas.com%2Fstatus-for-compute-manager-shows-as-down-in-nsx-t-manager%2F&amp;linkname=Connection%20Status%20for%20Compute%20Manager%20shows%20as%20Down%20in%20NSX-T%20Manager" title="Facebook" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_twitter" href="https://www.addtoany.com/add_to/twitter?linkurl=https%3A%2F%2Fwww.burakaktas.com%2Fstatus-for-compute-manager-shows-as-down-in-nsx-t-manager%2F&amp;linkname=Connection%20Status%20for%20Compute%20Manager%20shows%20as%20Down%20in%20NSX-T%20Manager" title="Twitter" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_whatsapp" href="https://www.addtoany.com/add_to/whatsapp?linkurl=https%3A%2F%2Fwww.burakaktas.com%2Fstatus-for-compute-manager-shows-as-down-in-nsx-t-manager%2F&amp;linkname=Connection%20Status%20for%20Compute%20Manager%20shows%20as%20Down%20in%20NSX-T%20Manager" title="WhatsApp" rel="nofollow noopener" target="_blank"></a><a class="a2a_button_email" href="https://www.addtoany.com/add_to/email?linkurl=https%3A%2F%2Fwww.burakaktas.com%2Fstatus-for-compute-manager-shows-as-down-in-nsx-t-manager%2F&amp;linkname=Connection%20Status%20for%20Compute%20Manager%20shows%20as%20Down%20in%20NSX-T%20Manager" title="Email" rel="nofollow noopener" target="_blank"></a></p><p>The post <a href="https://www.burakaktas.com/status-for-compute-manager-shows-as-down-in-nsx-t-manager/">Connection Status for Compute Manager shows as Down in NSX-T Manager</a> appeared first on <a href="https://www.burakaktas.com">BURAK AKTAŞ</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
